Overview
Enviro Forest Handheld spectrum analyzer High protection portable design, sturdy and durable can be used in laboratory, more suitable for field mobile use built-in large capacity lithium battery, can work for more than 4 hrs. 18650 rechargeable battery. USB or LAN communication, easy for long-range control. 5.6 in highlight color display, 640 X 480 resolution, waveform display clearly.
Features
- High protection portable design, sturdy and durable, can be used in laboratory
- Built-in large capacity lithium battery, can work for more than 4 hrs
- 6 in highlight color display, 640 x 480 resolution, waveform display clearly
- Integration USB Host & Device, support USB flash disk memory
- Its PC software can achieve the management and storage of testing data
- Aerospace and Defense: Radio and Radar, interferometric analysis, site repairment
- Wireless service provider: interferometric analysis, site repairmen
- TV & Radio: interferometric analysis, check of channel power
- Spectrum management agency: spectrum monitor
Technical Specifications
| Frequency Range | 9 KHz to 1.6G Hz AC Coupled 5 M to 1.6 GHz |
| Frequency Resolution | 1 Hz |
| Reference Frequency | 10 MHz |
| Frequency Readout Accuracy | ± (frequency indication * frequency reference uncertainty+ 1 % x span + 20 % RBW + marker resolution + 1 Hz) |
| Marker Resolution | (Frequency span) or (number of sweep points -1) |
| Resolution Bandwidth | |
| -3 dB Bandwidth | 10 Hz to 1 MHz,1 to 3 to 10 sequence |
| Accuracy | ± 5 % RBW =10 Hz to 1 MHz nominal |
| Resolution Filter Shape Factor | < 5:1 nominal |
| Carrier Offset | 10 K < -92 dBc/Hz, typical -95 dBc/Hz30 K < -93 dBc/Hz, typical -96 dBc/H
100 K < -95 dBc/Hz, typical -97 dBc/Hz 1 MHz < -117 dBc/Hz, typical -119 dBc/Hz |
| Sweep Time | |
| Range | Span > 100 Hz 2 ms to 1000 sSpan = 0 Hz 600 ns to 200 s |
| Sweep Mode | Continuous, single |
| Trigger Source | Free run; video; external |
| Trigger slope | Selectable positive or negative edge |
| Counter Resolution | 1 Hz |
| Accuracy | ± (marker frequency × frequency reference uncertainty + counter resolution) |
| Log Scale and Units | 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed |
| Linear Scale and Units | 0 to 100 %, 10 divisions displayed |
| Scale Unit | dBm, dBmV, dBuV, Watts, Volts |
| Sweep (Trace) Points | 461 |
| Number of Markers | 4 |
| Detectors | Normal, positive peak, sample, negative peak, RMS |
| Number of Traces | 4 |
| Trace Functions | Clear or write, maximum hold, minimum hold, average, check, close |
| Level Measurement Error | ±1.5 dB (excluding input VSWR mismatch)68 °F to 86 °F (20 ℃ to 30 ℃), peak detector, preamplifier off, input signal -50 dBm to 0dBm |
| Setting Range | -100 dBm to +30 dBm, steps of 1 dB |
| Reference Input Frequency | 10 MHz |
| Reference Input Amplitude | 0 dBm to 10 dBm |
| Trigger Voltage | 5V TTL level |
| Connector and Output Impendence | N female; (50 Ω) |
| Display Index | 5.7 inch, 640 x 480 resolution,64 M color LCD display |
| Temperature Range | |
| Working | 14 °F to 122 °F (-10 ℃ to +50 ℃), 32 °F to 122 °F (battery: 0 ℃ to 50 ℃) |
| Storage | -40 °F to 158 °F (-40 ℃ to +70 ℃), -4 °F to 122 °F (battery: -20 ℃ to 50 ℃) |
| Relative Humidity | < 95 % |
| Power | Input voltage range: DC: 12 V to 17 V, maximum 2.8 A input 220 VAC ±15%AC frequency range: 40 Hz to 60 Hz
Power consumption: Maximum 32 W |
| Size | 10.23 in x 8.66 in x 2.95 in (260 mm x 220 mm x 75 mm) |
| Weight | 6.39 lb (2.9 kg) |











Reviews
There are no reviews yet.